REPORT OF TEST

Sterilray GermBuster Sabre

PHOTO/RADIO/SPECTRO/GONIOMETRIC ASSAY


The OSLUV Project

680 Transfer Road, Suite 3B, St. Paul, MN

<contact-assay@osluv.org>


Catalog ID f512edd9-08a0-4892-9396-bcf375f0d120

Rev R00 — December 11, 2023


Contents

1. —
Radiant Intensity Pattern
2. —
Warm-Up behavior
3. —
Burn-In behavior
4. —
Spectral Output
5. —
Exposure Limits
6. —
Roll-Dependence
7. —
R² Validation
8. —
Electrical Characteristics
9. —
Considered Article Details
10. —
Measurement Apparatus
11. —
Revisions
12. —
Appendices
Quick Facts
Power & Pattern
(All reported values after stabilization)
Total UVC Optical Power 316.9mW
1m Peak Irradiance 12.7μW/cm²
Safety
Power above 240nm 19.6mW (6.2%)
Equivalent 222nm Eye S(λ) Power 889.3mW
\(w_s / S(222\mathrm{nm})\) (ANSI/IES Eye Limit) 280.6%
Considered Article
Manufacturer Sterilray, Inc
— Model Name GermBuster Sabre
— Model Number TBD
— Production Date Unknown
Acquisition Date November 2023
Acquisition Price $3950
Acquisition Method Purchased

Reference Image

§1: Radiant Intensity Pattern

Polar Radiant Intensity Plot

This chart displays a polar plot of the intensity pattern of the source. Only the forward-facing hemisphere was measured. The data was taken at 1000.0mm from the light source.

Data is reported in radiant intensity units of milliWatts per steradian. 1 mW/sr is equivalent to an irradiance of 0.1µW/cm² at a distance of one meter.


Axes Reference

Isoirradiance Plot (Projection onto surface at 1m)

This chart presents the irradiance a flat surface would receive with the tested lamp one meter above it pointed directly downward. Isoirradiance lines segment the chart by logarithmic irradiance boundaries (indicated.)